Unifi Port 8080 Is Used By Other Programs Startup Failed Due
- Unifi Port 8080 Is Used By Other Programs Startup Failed Due Coronavirus
- Unifi Port 8080 Is Used By Other Programs Startup Failed Due Diligence
- Unifi Controller Error Port 8080 Is Used By Other Programs
- Unifi Port 8080 Is Used By Other Programs Startup Failed Due Date
พอติดตั้งโปรแกรมของ Unifi แล้วพอจะไปตั้งค่าตัว Unifi AP มันขึ้นว่า Initializing UniFi Controller. Starting UniFi Controller. Port 8080 is used by other programs Start-up failed. Unifi Port 8080 Is Used By Other Programs Startup Failed Due 5/14/2018 Shot Full Of Love Billy Ray Cyrus Mp3 Download. Overview This article lists the ports used by the UniFi Controller. Initializing Unifi Controller Starting Unifi Controller Port 8080 in use by other programs Start-up failed.
Unifi Port 8080 Is Used By Other Programs Startup Failed Due Coronavirus
Ubiquiti provides instructions here for running the UniFi Controller as a service. What they don’t tell you is that when you try to upgrade the controller, you can’t, because the service is still running. Here are the instructions for that:
1. Back up your config from Settings > Maintenance > Download Backup. If you get the message, “There was an error generating a new backup file,” check %UserProfile%Ubiquiti UniFilogsserver.log for details. If it indicates that it could not create a file in a TEMP folder, try stopping and restarting the UniFi Controller service from Windows Services. That should recreate the folder(s) in TEMP and allow you do Download Backup.
Another alternative, if you haven’t made recent changes, is to go to Settings > Auto Backup and download the most recent backup.
2. On the server running the controller, open an administrative Command Prompt. Stop the UniFi Java service:
cd '%UserProfile%Ubiquiti UniFi'
java -jar libace.jar stopsvc
Unifi Port 8080 Is Used By Other Programs Startup Failed Due Diligence
3. Overinstall the new controller (run UniFi-installer.exe). On the last page of the install wizard, check “Start UniFi Controller after installation”.
4. In the small window that opens, wait until it says “UniFi Controller (x.xx.xx) started”:
Unifi Controller Error Port 8080 Is Used By Other Programs
Close the window (do not launch browser).
5. Back at the administrative Command Prompt, install and start the service:
java -jar libace.jar installsvc
java -jar libace.jar startsvc
6. Test access from a browser.
Additional Commands and Troubleshooting
To view other commands available, run java –jar libace.jar
without parameters. You’ll see:
Once the service is installed, you can check its status in the list of Windows Services. For example, here the service is present but it’s not running:
After upgrading the controller at one site to version 5.8.24, I could no longer access the controller inside the LAN on port 8443, although cloud access was working. Also, all devices showed as offline. When I logged in directly to the USG, it told me that the Controller was unreachable, even though it is on the same LAN, indicating that it could not “inform” to the controller on port 8080:
UniFi had already added TCP and UDP firewall exceptions on the server for mongod.exe, but apparently that is not enough. I added explicit exceptions on ports 8080 and 8443. After that, I was able to access the controller across the network on 8443, and the devices once again showed as connected.
Update August 29, 2020
With controller 5.14.23, and probably before, the service is no longer appearing in the list of services (services.msc). You can check for the service definition in the registry (HKLMSYSTEMCurrentControlSetServicesUniFi
). You can also manage the service from an administrative command prompt:
sc query UniFi
net stop UniFi
net start UniFi
Unifi Port 8080 Is Used By Other Programs Startup Failed Due Date
Rack-Mount Brackets (Qty. 2) |
Mounting Screws (Qty. 4) |
Security Screw |
Power Cord |
System Requirement
Either of the following is required:
- iOS or Android™ Mobile Device with UniFi Network App Installed
- Web Browser: Google Chrome (Other browsers may have limited functionality)
IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.
Touchscreen Display | |
---|---|
Bootup Animation | Initializing. |
Location Animation | This indicates that you clicked Locate in the UniFi Controller software. The software will also display the location of the device on the map. |
HDD LED | |
Flashing White | Indicates Read/Write Activity |
Steady Amber | Indicates HDD Error |
RJ-45 Speed/Link/Activity LED (Ports 1 - 9) | |
Off | No Link |
Amber | Link Established at 10/100 Mbps Flashing Indicates Activity |
Green | Link Established at 1 Gbps Flashing Indicates Activity |
SFP+ Speed/Link/Activity LED (Ports 10 - 11) | |
Off | No Link |
Green | Link Established at 1 Gbps Mukta kannada serial cast. Flashing Indicates Activity |
White | Link Established at 10 Gbps Flashing Indicates Activity |
HDD Bay | |
Install a 3.5' or 2.5' HDD (not included) to use the device as an NVR for UniFi Protect. | |
RJ45 LAN (Ports 1 - 8) | |
The RJ45 ports support 10/100/1000 Ethernet connections. By default, they are set to DHCP Server with the fallback IP address, 192.168.1.1/24. | |
RJ45 Internet (Port 9) | |
The RJ45 port supports a 10/100/1000 Ethernet connection. Set to DHCP Client by default. | |
SFP+ Internet (Port 10) | |
The SFP+ port supports a 1/10G Ethernet connection. Set to DHCP Client by default. | |
SFP+ LAN (Port 11) | |
The SFP+ port supports a 1/10G Ethernet connection. By default, it is set to DHCP Server with the fallback IP address, 192.168.1.1/24. | |
Reset Button | |
Resets to factory defaults. The device should be running after bootup is complete. Press and hold the Reset button for about 10 seconds until the display indicates that the device has reset itself. After a few seconds, the LED will turn off, and the device will automatically reboot. | |
USP RPS LED | |
Reserved for future use. | |
USP Connect DC Input | |
Reserved for future use. | |
Power Port | |
Connect the included Power Cord to the Power port. |
- Phillips screwdriver
- Standard-sized, 19' wide rack with a minimum of 1U height available
- For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
- For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.
We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable
Note: Although the cabling can be located outdoors, the UDM-Pro itself should be housed inside a protective enclosure. |
Ensure the device is powered off before you install the 3.5' or 2.5' HDD (not included).
OR
Removing an 3.5' HDD
OR
For information about compatible fiber SFP modules, visit: ubnt.link/UniFi_SFP_DAC_Compatibility
OR
You have the following options:
- Enable Bluetooth on your mobile device and use the UniFi Network app.
- Use a computer connected to the UDM-Pro on a LAN port. Go to “Chrome Instructions”.
UniFi Network App
- Follow the on-screen instructions.
Chrome Instructions
Use the Chrome web browser to set up your device.
- Ensure that your host system is on the same Layer 2 network as the UDM-Pro.
- Launch the Chrome web browser and go to https://setup.ui.com
- Follow the on-screen instructions of the Setup Wizard.
After you run the UniFi Setup Wizard, a login screen will appear for the UniFi Network Controller management interface. Enter the Username and Password that you created in the UniFi Setup Wizard. Then click Sign in.
You can manage your network and view network statistics using the UniFi Network Controller management interface. For information on using the UniFi Network Controller software, refer to the User Guide located on our website at: ui.com/download/unifi
UDM-Pro | |
Dimensions | 442.4 x 43.7 x 285.6 mm (17.42 x 1.72 x 11.24') |
---|---|
Weight | 3.90 kg (8.60 lb) |
With Mount Brackets | 3.99 kg (8.80 lb) |
Interfaces | |
Networking | (8) 10/100/1000 RJ45 LAN Ports (1) 10/100/1000 RJ45 WAN Ports (1) 1/10G SFP+ LAN Port (1) 1/10G SFP+ WAN Port |
Management | Ethernet In-Band (1) Bluetooth BLE |
Max. Power Consumption | 33W |
Power Method | (1) Universal AC Input, 100 to 240VAC (1) RPS DC Input |
Power Supply | Internal 50W/12V |
Supported Voltage Range | 100 - 240VAC |
Display | 1.3' Color Touch Panel |
LED | |
System | Status |
HDD | Activity |
RJ45 | Link/Speed/Activity |
SFP+ | Link/Speed/Activity |
Processor | Quad ARM Cortex-A57 Core at 1.7 GHz |
System Memory | 4 GB DDR4 |
On-Board Flash Storage | 16 GB eMMC |
Operating Temperature | -10 to 40° C (14 to 104° F) |
Operating Humidity | 5 to 95% Noncondensing |
Certifications | CE, FCC, IC |